EXPLORING THE POWER OF OUR BANALISERS
Discover the science of sterilization with our advanced banalisers. These precision instruments utilize high-pressure steam and temperature to eliminate harmful microorganisms, ensuring the utmost in hygiene and safety. Explore the diverse applications across healthcare, laboratories, and more, and learn how banalisers are essential for safeguarding public health and research integrity. Join us in unlocking the potential of banalisers for a cleaner, safer world
AVAILABLE IN SEVERAL CAPACITIES AND DIMENSIONS
Autoclave Sterilizer | Capacity (L) | Dimensions (mm) |
---|---|---|
SA500 | 200 | 800 |
SA800 | 250 | 1000 |
SA1200 | 300 | 1200 |
SA2000 | 400 | 1500 |
SA3500 | 600 | 1800 |
SA5200 | 800 | 2200 |
SA8000 | 1200 | 3000 |
Banaliser Data
Property | Value |
---|---|
Temperature | 147 °C |
Pressure | 0.35 MPA |
Steam | 8 bar |
Average Cycle Time | 30 min |
Treated Volume | 500-1200 Liters |
Average Waste Density | 100-150 Kg / m3 |
Average Treated Weight | 80–800 Kg |
Waste Volume Reduction | 80 % |
OPERATING PRINCIPLE
The Pre-Sterilization Phase: it is a question of adjusting the data of the exploitation and monitoring the treatment process via an es command or an automatic system by maintaining the first steam tank at a high temperature of 147 ° C and under high pressure of 0.35 MPA so that the operation of the sterilization of the Infectious risk Care activity waste (DASRI) is perfect.
The sterilization phase: it is a question of depositing the contaminated infectious risk care activity waste (DASRI) in a tank.After Filling the Tank, sterilization is started and is carried out on the basis of wet steam injection by a steam generator internal to the second tank and in an automatic manner. Thus, it must be ensured that the parts of the device are set at a sufficient temperature equal to 147 °C. is a pressure of 0.35MPA. The sterilization cycle remains 25 minutes
The post-sterilization phase: it involves Infectious risk Care activity waste (DASRI) already sterilized in the previous phase by a system designed and adapted for cooling on the basis of cold water ensuring a temperature of 40 ° C and for 8 minutes.………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….
The elimination phase: at the end of sterilization, the user opens the door and the drained solid waste is removed and placed in a container. The filtered, cooled and decontaminated liquids are evacuated via the wastewater network (sewers).…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….