EXPLORING THE POWER OF OUR BANALISERS

Discover the science of sterilization with our advanced banalisers. These precision instruments utilize high-pressure steam and temperature to eliminate harmful microorganisms, ensuring the utmost in hygiene and safety. Explore the diverse applications across healthcare, laboratories, and more, and learn how banalisers are essential for safeguarding public health and research integrity. Join us in unlocking the potential of banalisers for a cleaner, safer world

AVAILABLE IN SEVERAL CAPACITIES AND DIMENSIONS

Autoclave Sterilizer Capacity (L) Dimensions (mm)
SA500 200 800
SA800 250 1000
SA1200 300 1200
SA2000 400 1500
SA3500 600 1800
SA5200 800 2200
SA8000 1200 3000

 

Banaliser Data

Property Value
Temperature 147 °C
Pressure 0.35 MPA
Steam 8 bar
Average Cycle Time 30 min
Treated Volume 500-1200 Liters
Average Waste Density 100-150 Kg / m3
Average Treated Weight 80–800 Kg
Waste Volume Reduction 80 %

OPERATING PRINCIPLE

The Pre-Sterilization Phase: it is a question of adjusting the data of the exploitation and monitoring the treatment process via an es command or an automatic system by maintaining the first steam tank at a high temperature of 147 ° C and under high pressure of 0.35 MPA so that the operation of the sterilization of the Infectious risk Care activity waste (DASRI) is perfect.

The sterilization phase: it is a question of depositing the contaminated infectious risk care activity waste (DASRI) in a tank.After Filling the Tank, sterilization is started and is carried out on the basis of wet steam injection by a steam generator internal to the second tank and in an automatic manner. Thus, it must be ensured that the parts of the device are set at a sufficient temperature equal to 147 °C. is a pressure of 0.35MPA. The sterilization cycle remains 25 minutes

The post-sterilization phase: it involves Infectious risk Care activity waste (DASRI) already sterilized in the previous phase by a system designed and adapted for cooling on the basis of cold water ensuring a temperature of 40 ° C and for 8 minutes.………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….

The elimination phase: at the end of sterilization, the user opens the door and the drained solid waste is removed and placed in a container. The filtered, cooled and decontaminated liquids are evacuated via the wastewater network (sewers).…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………….